SHW18A
Lock and Leave (L&L) Transparent Door
Security Hardware - 18A
Guidelines:
The L&L door will be the last door exited from a building after all
other exterior doors have been secured from the Interior. This hardware group
utilizes controlled key lockup in conjunction with two additional locking
mechanisms: the electric latch panic exit device (22a) and the continuously
engaged electromagnetic lock (30). Upon building lockup, the Cypher lock
(4) is deactivated by switch (50) located in key box (48). The deadbolt
(49) is key engaged to complete the lockup sequence. The RX sensor switch
will release the electromagnetic lock. During normal business hours the
guard has override capability of the RX switch.
| Diagram Key No. |
Quantity |
Manufacturer |
Description |
Par/Model No. |
|
|
|
|
|
|
| (4) |
1 |
Continental Instruments (or equal,
see Note #1) |
Cypher Lock (access control) |
SB-24-110 |
| (5) |
Varies |
Adams Rite (Note #2) |
Certified Forced Entry Lock x
Manufacturer |
Adams
Rite MS 185OS 15TT Thumbturn |
| (10) |
1 |
LCN |
Door Closer |
4041 x Cush-n-Stop x Finish |
| (13) |
Varies |
Roton (Note #2) |
Certified Hinge x Manufacturer |
Roton
780-112HD |
| (21a) |
1 |
Von
Duprin (Note #3) |
Electric Power Transfer |
EPT-1024 x Finish |
| (22a) |
1 |
Von
Duprin (see Notes #3,#4,#5 & #6) |
Panic Exit Device (access control) |
RXEL99NL x 990NL-R Trim less
cylinder x 299F strike x Finish |
| (30) |
1 |
Dynalock
(Note #6) |
Electromagnetic Locking Device
(emergency lock) |
2268/25V-10 x MBS |
| (48) |
1 |
Knox
(or DS approved equal) |
Recessed Mount Key Control Lockbox
(w/ Combination Lock) |
4400-GC1 |
| (49) |
1 |
ASSA
(See Notes #2, #7, & #8) |
High Security Deadbolt Lock ( w/
Interior Thumbturn) |
6000 x Finish x 2 3/4 x D |
| (50) |
1 |
Generic |
Double Pole Single Throw Toggle
Switch (Rating: 1 amp@24VDC or greater) |
Generic |
| (18) |
1 |
Sentrol |
Magnetic Switch (door monitor) |
1076D |
ff - finish , hh - handing , kk - keyway , pp - packaging , LH -
lever handle
*NOTES:
-
Power to the EL99 must be provided by an AES 726 or 926
power supply. The Continental Cypher lock may be substituted with a
DS- Approved automated access system.
-
For non-forced entry doors, substitute McKinney (or
equivalent) non-removable pin hinges (1 and 1/2 pair) for the certified
hinge, a Medeco Maxim Deadbolt with removable Medeco core for the ASSA
deadbolt, and eliminate the manufacturer's forced entry locks. The
combination lock key container (48) and Toggle Switch (50) are optional.
-
The Von Duprin Electric Power Transfer (21a) and RX sensor
switch (Von Duprin Part #050226) may be ordered as separate items to field
upgrade an existing Von Duprin EL99.
-
Existing EL99 panic exit devices equipped with the dogging
feature must have the mechanical housing cover plate reversed, to prevent the
dogging of the electric latch.
-
The RX option is not required on door having automated
access readers on both the Interior and exterior side for entry/exit
monitoring and anti-passback. This design requires that the
electromagnetic lock be incorporated into the fire alarm system to prevent
emergency deactivation.
-
DS-approved alternative hardware with comparable locking
force may be utilized in substitution of the electric locking
hardware. A/FBO/PE/CSM shall be consulted on all projects that are
A/FBO funded.
-
The ASSA deadbolt with key (49) must be procured thru
DS/PEL/SEM.
-
The ASSA deadbolt (49) key is to be securely tethered to the
Interior of the Key Lockbox (48). The tether should be of chain type
material and of a thickness sufficient to withstand daily use.
|